Baxter Sigma Spectrum Infusion System (V6 Platform), Product Code 35700BAX

Baxter Healthcare Corporation · There is the potential for missing motor mounting screws, which may have occurred during the servicing process.

Open, ClassifiedUnder Investigation by firmZ-1253-2025
Open FDA's page for this record
Cfres ID
212492
Product res number
Z-1253-2025
Event date initiated
2025-02-05
Event date posted
2025-03-06
Recall status
Open, Classified
Res event number
96289
Product code
FRN
Product description
Baxter Sigma Spectrum Infusion System (V6 Platform), Product Code 35700BAX
Firm FEI number
1417572
Recalling firm
Baxter Healthcare Corporation
Address 1
1 Baxter Pkwy
City
Deerfield
State
IL
Postal code
60015-4625
Additional info contact
Center for One Baxter 800-422-9837
Reason for recall
There is the potential for missing motor mounting screws, which may have occurred during the servicing process.
Root cause description
Under Investigation by firm
Product quantity
66 units
Distribution pattern
US: Nationwide
Code info

UDI/DI 00085412091570, Serial Numbers: 704198, 728888, 751492, 758399, 758614, 761662, 763197, 766291, 772611, 773302, 775486, 778837, 785425, 793453, 795240, 798065, 814485, 818850, 826637, 850214, 850854, 851500, 854157, 855803, 863354, 870307, 873114, 876483, 877014, 877102, 889153, 896292, 900181, 906422, 907176, 912242, 913562, 927864, 938265, 958176, 962828, 963975, 965158, 974676, 981605, 982459, 984154, 986132, 986634, 989053, 993087, 994417, 994842, 995538, 997153, 1006359, 1011058, 1013925, 1014064, 1014529, 1014856, 1017150, 1017546, 1018229, 1018703, 1024109

Action

Baxter issued an "URGENT MEDICAL DEVICE RECAL" notice to its consignees on 02/05/2025 via US Mail. The notice explained the issue, hazard involved, and requested the following actions be taken: "1. Immediately locate, isolate, and cease all use of Spectrum pumps with the affected serial numbers. The product code and serial number can be found on the bottom of the infusion pump. 2. Contact Baxter to arrange for the return of the affected pumps for inspection and reservicing as applicable. 3. If you received this communication directly from Baxter, acknowledge receipt on the enclosed reply form even if you have no remaining inventory. If you do not complete the acknowledgement, you will receive a phone call from OnProcess Technology on behalf of Baxter to confirm your receipt of this notification. 4. If you purchased this product from a distributor or wholesaler, please note that responding on the Baxter customer portal is not applicable. If a response is requested by your distributor or wholesaler, please respond to them according to their instructions. 5. Please forward a copy of this communication to all departments within your institution who use the affected product. 6. If you are a dealer, wholesaler, distributor/reseller, or original equipment manufacturer (OEM) that distributed any affected product to other facilities, please conduct a user-level recall of the affected product that you distributed to customers and check the associated box on the customer portal. For general questions regarding this communication, or quality problems, please contact your Baxter sales representative, or Baxter Global Technical Services at 800-843-7867 Monday through Friday, between 7:00 am and 7:00 pm Eastern Time."

K numbers
K133801
Harmonized identifiers (openFDA)
Device name
Pump, Infusion
Medical specialty description
General Hospital
Regulation number
880.5725
Device class
2
K number
K052219, K922074, K983321, K032642, K101194, K091855, K880623, K850488, K931549, K791720, K944721, K801704, K003543, K864997, K011096, K844719, K890862, K915407, K822454, K891583, K961862, K042432, K910007, K812035, K921050, K896593, K090736, K871084, K932895, K990518, K800569, K124053, K883902, K043600, K994374, K865058, K214045, K823204, K895709, K913661 +809 more
Registration number
1526611, 1055927, 2320968, 2027804, 3018094310, 3008058400, 3013298431, 9617594, 3003927385, 3009456923, 3005382983, 3011688490, 2029015, 3012302888, 2244478, 9617787, 1061124, 1314417, 1054713, 3004548776, 3013764800, 3010564249, 1320894, 2024022, 2523676, 9610825, 9681819, 1921846, 3007738736, 9680425, 3006534321, 9680741, 3020777588, 1018470, 3013722099, 1220973, 3000240707, 3004112621, 3009754410, 3016798778 +108 more
FEI number
1526611, 3018094310, 3008058400, 3013298431, 3003927385, 1000113359, 3003282181, 1000160458, 3009456923, 3005382983, 3011688490, 3012302888, 1314417, 3004548776, 3000957797, 3000206435, 3001236905, 3013764800, 3010564249, 3002826093, 3003166194, 2648209, 1000138054, 2024022, 3003076831, 2523676, 1921846, 3000147578, 3007738736, 3006534321, 3020777588, 3002879021, 1018470, 3003767881, 3013722099, 3002807099, 3003513491, 1220973, 3000240707, 3004112621 +108 more