Device recalls

Access Erythropoietin (EPO), Catalog Number - A16364 a glycoprotein (~30,400 Daltons) produced primarily by the kidney, is the principal fa…

Beckman Coulter, Inc. · Affected lot (439363) exhibited a negative dose drop of -22% with native patient samples compared to alternate reagent lots. Patient samples tested with the af…

Open, ClassifiedUnknown/Undetermined by firmZ-1249-2025
Open FDA's page for this record
Cfres ID
212434
Product res number
Z-1249-2025
Event date initiated
2025-02-03
Event date posted
2025-02-28
Recall status
Open, Classified
Res event number
96255
Product code
GGT
Code info
Catalog A16364 UDI-DI 15099590201838 Lot 439363
Firm FEI number
2122870
Recalling firm
Beckman Coulter, Inc.
Address 1
1000 Lake Hazeltine Dr
City
Chaska
State
MN
Postal code
55318-1037
Additional info contact
Ian Pilcher 952-448-4848
Root cause description
Unknown/Undetermined by firm
Product quantity
498 US; 1576 OUS
Product description

Access Erythropoietin (EPO), Catalog Number - A16364 a glycoprotein (~30,400 Daltons) produced primarily by the kidney, is the principal factor regulating red blood cell production (erythropoiesis) in mammals. Renal production of EPO is regulated by changes in oxygen availability. Under conditions of hypoxia, the level of EPO in the circulation increases and this leads to increased production of red blood cells.

Reason for recall

Affected lot (439363) exhibited a negative dose drop of -22% with native patient samples compared to alternate reagent lots. Patient samples tested with the affected lot may demonstrate repeatable falsely decreased results, which may lead to improper diagnosis or repeat testing.

Action

Firm began notifying customers February 6, 2025. Customers were instructed to discontinue using and discard all remaining reagent packs of the Access EPO reagent lot identified. Customers are advised to share this recall with their medical director and perform a retrospective review of patient test results generated with this lot and assess the need for retesting.

Distribution pattern

Domestic distribution to AL AR AZ CA CT FL ID IL IN KS MA MI NC NE NJ NY OH OR PA TN TX UT WA WV. International distribution to Argentina, Australia, Austria, Belgium, Brazil, Bulgaria, Canada, China, Czechia, Denmark, France, Germany, Hungary, India, Italy, Japan, Korea, Republic of, Netherlands, Philippines, Russian Federation, Saudi Arabia, Slovakia, Spain, United Kingdom of Great Britain and Northern Ireland

K numbers
K052223
Harmonized identifiers (openFDA)
Device name
Assay, Erythropoietin
Medical specialty description
Hematology
Regulation number
864.7250
Device class
2
K number
K936016, K894943, K983203, K980737, K926390, K932650, K833957, K052223, K931666, K882686, K910481, K931756, K952559, K893393, K902639, K183088, K954898, K240182, K903492, K992799
Registration number
1222302, 3002800697, 8032314, 2432235, 2182501, 3002806944, 2025099, 2245285, 2122870
FEI number
3002808140, 3007981058, 3002800697, 1000121039, 2432235, 2182501, 3002806944, 2245285, 2122870