Device recalls

smiths medical Medfusion Model 3500 Syringe pump

Smiths Medical ASD Inc. · Medfusion syringe pumps, with software versions before v6.0.0, may have the following issues:1. Delivery During Motor Not Running High Priority Alarm, 2. Infus…

Open, ClassifiedSoftware Design ChangeZ-0863-2024
Open FDA's page for this record
Cfres ID
205366
Product res number
Z-0863-2024
Event date initiated
2023-12-19
Event date posted
2024-02-01
Recall status
Open, Classified
Res event number
93754
Product code
FRN
Product description
smiths medical Medfusion Model 3500 Syringe pump
Code info
All Medfusion Model 3500 pumps with software v3.X, v4.X, and v5.0.0 and was addressed in software v6.0.0 (2012) and all subsequent versions.
Firm FEI number
3012307300
Recalling firm
Smiths Medical ASD Inc.
Address 1
6000 Nathan Ln N
City
Minneapolis
State
MN
Postal code
55442-1690
Additional info contact
Field Corrections 763-383-3072
Root cause description
Software Design Change
Product quantity
93177 pumps
Distribution pattern
worldwide
Reason for recall

Medfusion syringe pumps, with software versions before v6.0.0, may have the following issues:1. Delivery During Motor Not Running High Priority Alarm, 2. Infusion Restarted with Incorrect Parameters, 3. Screen Lock, 4. Interruption of Bolus or Loading Dose Delivery, 5. Pump Displays Incorrect Bolus/Loading Dose, 6. Loading/Bolus Dose Below the Minimum Recommended Rate, 7. Motor Rate Error, 8. Incorrect Recall Last Settings, 9. Corrupt Configuration, 10. Auto Lock, 11. Toolbox Configuration Loading Dose Time Values. Smiths Medical corrected all issues included in this notification in previous software updates and the corrections were carried forward into all subsequent software releases. Please ensure you have the most recent Medfusion software (v6.0.0) installed on your pumps.

Action

Smiths Medical issued an URGENT MEDICAL DEVICE CORRRECTION notice to its consignees on 12/16/2023 by letter delivered via traceable means. The notice explained the issues with the pumps, the potential risks involved with their use, and requested the following actions be taken: 1. Locate all affected pumps in your possession and ensure all users or potential users of these devices are immediately made aware of this notification and proposed mitigations. Please ensure you have the most recent Medfusion software installed on your pumps. 2. Complete and return the attached Response Form to smithsmedical8045@sedgwick.com within ten days of receipt to acknowledge your understanding of this notification. 3. DISTRIBUTORS: If you have distributed potentially affected products to your customers, please immediately forward this notice to them. Request that they complete the response form and return it to smithsmedical8045@sedgwick.com. Inquires: To report adverse events or product complaints: Global Complaint Management, globalcomplaints@icumed.com, 1-(866)-216-8806 Additional information or technical assistance: Technical Support, icumed.custhelp.com/app/market-action Questions about this Field Correction Notice: Field Corrections, icumed.custhelp.com/app/market-action

K numbers
K040899
Harmonized identifiers (openFDA)
Device name
Pump, Infusion
Medical specialty description
General Hospital
Regulation number
880.5725
Device class
2
K number
K874546, K772094, K982170, K980751, K875348, K910425, K953731, K000842, K760370, K811918, K053554, K892210, K903788, K890736, K083689, K882249, K944733, K941595, K873776, K861001, K921050, K791720, K133532, K832641, K830017, K032147, K042405, K860353, K843772, K861539, K792050, K830605, K013767, K871807, K101194, K023083, K830490, K953098, K861598, K062699 +809 more
Registration number
3024122953, 3003927385, 3010273872, 9681819, 1721686, 2523167, 3002879653, 3011270181, 3015972753, 2520313, 3005700264, 1423507, 2027804, 3047799708, 3000204189, 3012494290, 1722139, 1928237, 3004491689, 3014732157, 3017636737, 1723170, 2521402, 3005768810, 1058584, 3015158050, 3013652261, 3004167615, 2528981, 3004112621, 1123137, 3008513006, 3015192982, 3018094310, 3029973819, 2030624, 3009746061, 1061124, 2016493, 1320894 +108 more
FEI number
3024122953, 3003927385, 1000114111, 3010273872, 1721686, 2523167, 3002879653, 3011270181, 3015972753, 2520313, 1000117172, 3005700264, 3002999813, 3003807466, 1000306431, 3047799708, 3000204189, 3012494290, 1928237, 3004491689, 3014732157, 3017636737, 2521402, 3005768810, 3015158050, 3001155023, 3013652261, 3004167615, 1000512168, 2528981, 3004112621, 3008513006, 3007596547, 3002807099, 3015192982, 3018094310, 3029973819, 3009746061, 1000121050, 2016493 +108 more
Wholesale access for licensed clinicians.

Free to join: your NPI is checked against the federal registry at signup, then wholesale pricing and the professional shelves open.

Data from openFDA, FDA's public API. FDA says not to rely on it to make decisions about medical care and to treat every result as unvalidated; confirm against FDA's own record and the product labeling. Not medical or legal advice.