Device recalls

Direxion Torqueable Microcatheter, NGMC/SINGLE/021/STRAIGHT/1RO/105; Material Number: M001195200

Boston Scientific Cork, Ltd. · The product is defective due to insufficient UV curing of the hydrophilic coating which is present on the outer surface of the distal segment of the microcathe…

Open, ClassifiedProcess controlZ-0223-2027
Open FDA's page for this record
Cfres ID
222851
Product res number
Z-0223-2027
Event date initiated
2026-09-16
Event date posted
2026-10-22
Recall status
Open, Classified
Res event number
99906
Product code
KRA
Product description
Direxion Torqueable Microcatheter, NGMC/SINGLE/021/STRAIGHT/1RO/105; Material Number: M001195200
Firm FEI number
3002913962
Recalling firm
Boston Scientific Cork, Ltd.
Address 1
Boston Scientific Limited, Business And Technology Park, Model Farm Road Boston Scientific Limited Business And Technology Park Model Farm Road
City
Cork
Country
Ireland
Additional info contact
Clara Johnson 763-494-1133
Root cause description
Process control
Product quantity
126
Code info

Material Number: M001195200; UDI-DI: 08714729839316; Batch Numbers: 37942457, 37999053, 38224527, 38304916, 38415911, 38687159, 38707977, 38916519, 39029416, 39029419, 39029640, 39092278, 40476286, 40479386, 40523958, 40525677;

Reason for recall

The product is defective due to insufficient UV curing of the hydrophilic coating which is present on the outer surface of the distal segment of the microcatheters and raised ridges on nitinol sleeves due to laser cutting misalignment.

Action

On September 16, 2026, Urgent Medical Device Removal - Immediate Action Required letters were sent to customers. Actions to be taken: 1. Immediately stop further use or distribution and segregate affected product (see Attachment 1 for identification of the affected devices). 2. Forward this notice to relevant personnel and any facilities to which the product was transferred. 3. Continue to follow the standard of practice when monitoring patients treated with the product. 4. Complete and return the enclosed Reply Verification Tracking Form per the included instructions. 5. Return product to Boston Scientific in accordance with the enclosed instructions.

Distribution pattern

Worldwide distribution US Nationwide and territory of Puerto Rico. The countries of Albania, Argentina, Australia, Austria, Belgium, Brazil, Canada, Chile, China, Colombia, Costa Rica, Croatia, Czech Republic, Denmark, Ecuador, Finland, France, Germany, Greece, Hungary, Ireland, Israel, Italy, Japan, Jordan, Kuwait, Lebanon, Lithuania, Mexico, Moldova, Netherlands, New Zealand, Norway, Panama, PERU, Poland, Portugal, Qatar, Romania, Russian Fed., Saudi Arabia, Serbia, Singapore, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Tunisia, T¿rkiye, UAE, United Kingdom.

K numbers
K163701
Harmonized identifiers (openFDA)
Device name
Catheter, Continuous Flush
Medical specialty description
Cardiovascular
Regulation number
870.1210
Device class
2
K number
K030688, K896819, K161962, K072724, K935349, K081147, K071468, K093750, K132947, K111490, K974473, K201907, K954949, K945593, K123477, K812173, K962129, K032494, K170931, K994155, K961668, K161967, K040139, K182071, K213442, K801829, K210339, K972518, K052841, K905447, K770432, K034036, K020680, K211110, K191305, K043538, K070279, K080737, K964154, K050630 +137 more
Registration number
3040099838, 3002806337, 3031823122, 3017823876, 3005941719, 3014498720, 2032112, 3008824097, 3009380063, 1000121056, 3010334444, 3004415014, 1220948, 2134812, 3045042524, 3006950086, 3003120897, 3014590708, 3011137372, 3012536737, 1718873, 1721686, 3000126629, 1319639, 1644312, 8010026, 2183870, 3005160949, 3009756153, 1721676, 1721504, 2183744, 1724474, 3017208642, 1928237, 1319211, 3010909876, 2024311, 9615817, 3014758755 +109 more
FEI number
3040099838, 3002806337, 3031823122, 3017823876, 3014498720, 3008824097, 3009380063, 1000121056, 3010334444, 3004415014, 1220948, 3045042524, 3006950086, 3002534070, 3003120897, 3014590708, 3012536737, 1718873, 1721686, 3008133910, 3000126629, 3002806565, 2183870, 3005160949, 3009756153, 1721676, 2828, 3005747797, 1721504, 1000220862, 2183744, 3002806476, 3017208642, 1928237, 1319211, 3010909876, 2024311, 3014758755, 3013556777, 3015151147 +109 more
Wholesale access for licensed clinicians.

Free to join: your NPI is checked against the federal registry at signup, then wholesale pricing and the professional shelves open.

Data from openFDA, FDA's public API. FDA says not to rely on it to make decisions about medical care and to treat every result as unvalidated; confirm against FDA's own record and the product labeling. Not medical or legal advice.